欧美激情另类 I 精品自在线 I 在线免费观看毛片视频 I 精品亚洲成a人片在线观看 I 日韩视频在线观看视频 I 久热精品免费视频 I 亚洲色欲色欲欲www在线 I 国产av永久无码青青草原 I 欧美一区二区高清 I 久久精品99久久久久久2456 I 免费操视频 I 国产精品视频久久久久久久 I 久久在线中文字幕 I 国产在线第一区二区三区 I 国产精品亚洲一区二区三区 I 日本高清va在线播放 I yy成人综合网 I www.夜色.com I 亚洲精品精品 I 成人中文视频 I 麻豆国产人妻欲求不满谁演的 I 恋夜久久 I 国产激情亚洲 I 国产91免费观看 I 日本亚洲色大成网站www久久 I 国产精品大全 I 69午夜视频 I 少妇极品熟妇人妻无码 I 污免费在线观看 I 99久热re在线精品99 6热视频 I 88精品视频 I 日韩av色在线 I 黄色三级高清 I 中国色在线 日|韩 I 欧美精品一区二区高清在线观看

2020 官網升級中!現在您訪問官網的瀏覽器設備分辨率寬度低于1280px
請使用高分辨率寬度訪問。

Consultation hotline:400-021-6779
Division of experimental grade of lightning surge tester
Release time: 2022-04-23Views: 1,417

Test method of lightning surge tester:

The cause of lightning surge tester is switching transient and lightning transient of power system; The purpose of Surge immunity test is to establish a common benchmark to evaluate the performance of electrical and electronic equipment under surge (impact). According to the general requirements of standard iec61000-4-5 surge impulse immunity test, the lightning surge generator simulates 1.2/50us voltage waveform, 8/20us current waveform and combined wave (voltage waveform: 10/700us, current waveform: 5/320us), and couples the waveform to the circuit under test through the coupling network, which has achieved the experimental purpose. Soxin electronic EMC laboratory is able to provide customers with surge test solutions of various combined waveforms.

Lightning surge tester test level:

The test levels of lightning surge tester are divided into levels 1, 2, 3, 4 and X according to the severity of voltage, of which X and are open levels. The corresponding voltage intensity of each level is shown in Table 1. The application scope of severity level depends on the environment (environment subject to surge possibility) and installation conditions. It is generally classified according to the following conditions: Level 1: better protected environment, such as the control room of the factory or power station. Level 2: a certain protected environment, such as a factory without strong interference. Level 3: ordinary electromagnetic disturbance environment, without special installation requirements for equipment, such as ordinary installed cable network, industrial workplace and substation. Level 4: severely disturbed environment, such as civil overhead lines and unprotected high-voltage substations. Level X: special level, which shall be determined after negotiation between the user and the manufacturer. The level of specific products is generally determined by product standards.

Test results of lightning surge tester:

The lightning surge tester test is a destructive test, which can be divided into the following situations according to the damage degree of the tested object:

a) The performance is normal within the limits specified by the manufacturer, the client or the buyer

b) The function or performance is temporarily lost or reduced, but it can recover automatically after the disturbance stops without operator intervention;

c) The function or performance is temporarily lost or reduced, but it can be recovered only after the intervention of the operator;

d) Unrecoverable function loss or performance degradation caused by equipment hardware or software damage or data loss.

 